Top Suppliers Transmission Line Surge Arrester - ZW7/CT(built-in) 35kV Outdoor Transformer Substation Vacuum Circuit Breaker – Aiso

Top Suppliers Transmission Line Surge Arrester - ZW7/CT(built-in) 35kV Outdoor Transformer Substation Vacuum Circuit Breaker – Aiso
As a way to provide you advantage and enlarge our organization, we even have inspectors in QC Crew and guarantee you our greatest assistance and product or service for Drop Out Fuse, Lightning Arrester Counter, Step Down Power Transformer, Since the manufacturing facility founded, we have now committed on the progress of new products. While using the social and economic pace, we are going to continue to carry forward the spirit of "high high-quality, efficiency, innovation, integrity", and persist with the operating principle of "credit to start with, customer initially, top quality excellent". We'll make a amazing long run in hair output with our companions.
Top Suppliers Transmission Line Surge Arrester - ZW7/CT(built-in) 35kV Outdoor Transformer Substation Vacuum Circuit Breaker – Aiso Detail:

Product Description

ZW7/CT(built-in) 35kV Outdoor Transformer Substation Vacuum Circuit Breaker :

Applicable place: (Suitable for frequent operating places)

1.Urban,rural network.

2.Industrial enterprises.

It is mainly used in outdoor 40.5KV distribution system to control and protect.

 

 

Advantages

1.It conforms to GB1984-89 and IEC56“AC high voltage circuit breaker”.

2.It can be charged and switched by remote control switch or by hand.

3.Good sealing, anti-aging, high pressure, no burning, no explosion, long life, convenient installation and maintenance features.

4.It is composed of spring operating mechanism or electromagnetic operating mechanism.

5.Its overall structure is supported by porcelain insulator, vacuum interrupter built in upper insulator, downside insulator used for supporting. The breaker applies

 

 

Environmental Conditions 

Ambient temperature:-15°C~+40°C
Relative humidity:≤95%or≤90%

The daily average saturated vapor pressure:≤2.2KPa;

The monthly average value:≤1.8KPa.

Altitude:≤1000m

Seismic intensity:≤8

*No fire, explosion, serious filthy, chemical corrosion and violent vibration of places.

 

Main Technical Parameters

Description

Unit

Data

Rated voltage

KV

33/35/36

Rated current

A

630/1250

Rated frequency

Hz

50/60

Rated short-circuit brekaing current

kA

20/25/31.5/40

Meachical life

 Time

10000

Note:Please contact the factory to confirm the latest parameters

Overall and installation dimension

ZW7/CT(built-in) 35kV Outdoor Transformer Substation Vacuum Circuit Breaker
 

Product detail pictures:

Top Suppliers Transmission Line Surge Arrester - ZW7/CT(built-in) 35kV Outdoor Transformer Substation Vacuum Circuit Breaker – Aiso detail pictures

Top Suppliers Transmission Line Surge Arrester - ZW7/CT(built-in) 35kV Outdoor Transformer Substation Vacuum Circuit Breaker – Aiso detail pictures

Top Suppliers Transmission Line Surge Arrester - ZW7/CT(built-in) 35kV Outdoor Transformer Substation Vacuum Circuit Breaker – Aiso detail pictures


Related Product Guide:

Being supported by an highly developed and skilled IT group, we could offer you technical support on pre-sales & after-sales support for Top Suppliers Transmission Line Surge Arrester - ZW7/CT(built-in) 35kV Outdoor Transformer Substation Vacuum Circuit Breaker – Aiso, The product will supply to all over the world, such as: Latvia, Tanzania, Thailand, We have gained a lot of recognition among customers spread all across the world. They trust us and always give repetitive orders. Furthermore, mentioned below are some of the major factors that have played significant role in our tremendous growth in this domain.
Leave Your Message
Send Your Inquiry Now