Super Purchasing for Expulsion Drop Out Fuse - ZW7/CT(built-in) 35kV Outdoor Transformer Substation Vacuum Circuit Breaker – Aiso

Super Purchasing for Expulsion Drop Out Fuse - ZW7/CT(built-in) 35kV Outdoor Transformer Substation Vacuum Circuit Breaker – Aiso
Each individual member from our large performance revenue crew values customers' needs and company communication for Zinc Oxide Surge Arrester, Changeover Switch 250a, Power Isolation Transformer, We are keeping durable business relationships with more than 200 wholesalers in the USA, the UK, Germany and Canada. If you are interested in any of our products, please feel free to contact us.
Super Purchasing for Expulsion Drop Out Fuse - ZW7/CT(built-in) 35kV Outdoor Transformer Substation Vacuum Circuit Breaker – Aiso Detail:

Product Description

ZW7/CT(built-in) 35kV Outdoor Transformer Substation Vacuum Circuit Breaker :

Applicable place: (Suitable for frequent operating places)

1.Urban,rural network.

2.Industrial enterprises.

It is mainly used in outdoor 40.5KV distribution system to control and protect.

 

 

Advantages

1.It conforms to GB1984-89 and IEC56“AC high voltage circuit breaker”.

2.It can be charged and switched by remote control switch or by hand.

3.Good sealing, anti-aging, high pressure, no burning, no explosion, long life, convenient installation and maintenance features.

4.It is composed of spring operating mechanism or electromagnetic operating mechanism.

5.Its overall structure is supported by porcelain insulator, vacuum interrupter built in upper insulator, downside insulator used for supporting. The breaker applies

 

 

Environmental Conditions 

Ambient temperature:-15°C~+40°C
Relative humidity:≤95%or≤90%

The daily average saturated vapor pressure:≤2.2KPa;

The monthly average value:≤1.8KPa.

Altitude:≤1000m

Seismic intensity:≤8

*No fire, explosion, serious filthy, chemical corrosion and violent vibration of places.

 

Main Technical Parameters

Description

Unit

Data

Rated voltage

KV

33/35/36

Rated current

A

630/1250

Rated frequency

Hz

50/60

Rated short-circuit brekaing current

kA

20/25/31.5/40

Meachical life

 Time

10000

Note:Please contact the factory to confirm the latest parameters

Overall and installation dimension

ZW7/CT(built-in) 35kV Outdoor Transformer Substation Vacuum Circuit Breaker
 

Product detail pictures:

Super Purchasing for Expulsion Drop Out Fuse - ZW7/CT(built-in) 35kV Outdoor Transformer Substation Vacuum Circuit Breaker – Aiso detail pictures

Super Purchasing for Expulsion Drop Out Fuse - ZW7/CT(built-in) 35kV Outdoor Transformer Substation Vacuum Circuit Breaker – Aiso detail pictures

Super Purchasing for Expulsion Drop Out Fuse - ZW7/CT(built-in) 35kV Outdoor Transformer Substation Vacuum Circuit Breaker – Aiso detail pictures


Related Product Guide:

Our improvement depends on the superior equipment, excellent talents and continuously strengthened technology forces for Super Purchasing for Expulsion Drop Out Fuse - ZW7/CT(built-in) 35kV Outdoor Transformer Substation Vacuum Circuit Breaker – Aiso, The product will supply to all over the world, such as: Argentina, Thailand, Liberia, With the technology as the core, develop and produce high-quality products according to the diverse needs of the market. With this concept,the company will continue to develop products with high added values and continuously improve products,and will provide many customers with the best products and services!
Leave Your Message
Send Your Inquiry Now