Special Design for Hrc Fuse Link 63 Amp - ZW7/CT(built-out) 35kV Outdoor Transformer Substation Vacuum Circuit Breaker – Aiso

Special Design for Hrc Fuse Link 63 Amp - ZW7/CT(built-out) 35kV Outdoor Transformer Substation Vacuum Circuit Breaker – Aiso
We insist on offering premium quality manufacturing with superior business concept, honest product sales as well as finest and fast assistance. it will bring you not only the good quality product or service and huge profit, but the most significant is to occupy the endless market for Lightning Arrester Counter, Power Capacitor, Small Power Transformer, We welcome new and old shoppers to make contact with us by telephone or mail us inquiries by mail for foreseeable future company associations and attaining mutual achievements.
Special Design for Hrc Fuse Link 63 Amp - ZW7/CT(built-out) 35kV Outdoor Transformer Substation Vacuum Circuit Breaker – Aiso Detail:

Product Structure

ZW7A-40.5 Series outdoor high voltage vacuum circuit breakers main switchgear of AC50Hz, 40.5KV, which is assembled with spring operating or electromagnetic operating mechanism. It can be operated to switch on/off by remote control, and it is also charged and switched on/off by hand. The design function of breaker complies with the requirements of GB1984-89 and IEC56 “AC high voltage circuit breaker”, it is mainly used in outdoor 35KV distribution system to control and protect, also for normal operating and protecting short circuit of urban,rural network, or industrial enterprises. Its overall structure is supported by porcelain insulator, vacuum interrupter built in upper insulator, downside insulator used for supporting. The breaker applies

frequent operating places with the advantages of good sealing anti-aging, high-voltage withstand, non flame, non explosion long working life, easy installation and maintenance and etc.

 

Product feature

For frequent operation place

Good sealing, anti-aging, high pressure, no burning, no explosion, long life, convenient installation and maintenance features

 

Ambient condition

1, Altitude:not exceed 1000m

2, Ambient temperature:not higher than +40°C,not less than – 15°C

3,Relative humidity:daily average relative humidity:≤95%;monthly average relative humidity :≤95%;monthly avergae relative humidity ≤90%, daily avergae saturated vapor pressure ≤2.2KPa;monthly average value: ≤1.8KPa.

4, Earthquake intensity: ≤8 degree

5, The installation should be free from fire,explosion,severe vibration,chemical corrosion and serious pollution.

 

Technical parameters

Item Description Data
1 Rated voltage(KV) 33/35
2 Rated insulation level(KV) 1min withstand voltage Dry 95
Wet 80
Lightning impulse withstand voltage(peak) 185
3 Rated current(A) 630
4 Rated short circuit breaking current(KA) 20/25/31.5/40
5 Rated operating sequence OC-0.3s-CO-180S-CO
6 Rated short-circuit opening times 20
7 Rated short circuit closing current(peak)(KA) 50/63/80
8 Rated peak withstand current(KA)
9 Rated short-circuit withstand current(KA) 20/25/31.5
10 Rated duration of short-circuit(S) 4
11 Aveage breake speed(m/s) 1.5±0.2
12 Average closing speed(m/s) 0.7±0.2
13 The jump time of contact close breake(ms) ≤2
14 Time difference of closing(breaking) three phase at the same time(ms) ≤2
15 Closing time(ms) ≤150
16 Opening time(ms) ≤60
17 Mechanical life 10000
18 Rated operating voltage and aux circuit rated voltage(V) DC110/220
AC110/220
19 DC resistance of circuit for every phase(S) ≤100
20 Contacts limit erosion(A) 3
21 Weight(KG) 1100

Outline dimension

In Stock Fast Delivery Outdoor 33kV 40.5kV Vacuum Circuit Breaker

 


Product detail pictures:

Special Design for Hrc Fuse Link 63 Amp - ZW7/CT(built-out) 35kV Outdoor Transformer Substation Vacuum Circuit Breaker – Aiso detail pictures

Special Design for Hrc Fuse Link 63 Amp - ZW7/CT(built-out) 35kV Outdoor Transformer Substation Vacuum Circuit Breaker – Aiso detail pictures


Related Product Guide:

abide by the contract", conforms into the market requirement, joins in the market competition by its good quality also as provides a lot more comprehensive and great company for purchasers to let them turn into huge winner. The pursue from the firm, would be the clients' gratification for Special Design for Hrc Fuse Link 63 Amp - ZW7/CT(built-out) 35kV Outdoor Transformer Substation Vacuum Circuit Breaker – Aiso, The product will supply to all over the world, such as: San Francisco, Mumbai, Uruguay, Ensuring high product quality by choosing the best suppliers, we have also implemented comprehensive quality control processes throughout our sourcing procedures. Meanwhile, our access to a large range of factories, coupled with our excellent management, also ensures that we can quickly fill your requirements at the best prices, regardless the order size.
Leave Your Message
Send Your Inquiry Now