We always continually offer you the most conscientious purchaser services, and the widest variety of designs and styles with finest materials. These efforts include the availability of customized designs with speed and dispatch for Wye Transformer Voltages, House Circuit Breaker, Transformer In Power System, Our company eagerly looks ahead to setting up long-term and pleasant small business partner associations with customers and businessmen from everywhere in the entire world.
Short Lead Time for Automatic Reset Circuit Breaker - Cabinet Used VS1 11kV 630A Indoor Vacuum Circuit Breaker – Aiso Detail:

Product Description

Cabinet Used VS1 11kV 630A Indoor Vacuum Circuit Breaker :

Frequency:50Hz   Rated voltage:12kV

Rated current:630kV   Interphase distance:210mm
Rated short-circuit breaking current:20kA   Fixed type
Double spring operating mechanism

Applicable place: (particularly to the places needing frequent operation)

1.the electrical equipment control and protection in industrial.

2.mining enterprises.

3.power plants.

4.substations.

It can be fixed in a switch cabinet or installed on a handcart.

Stable performance and easy installation.
Advantages

1.Simple structure.

2.Adapt ultra low resistance type vacuum interrupter.
3.Adapt optimization and modular spring operating mechanism.
4.Suitable for occasions with frequent operation.
5.Free maintenance and long service life.

6.High reliable performance.

Environmental Conditions 

Ambient temperature: - 40°C~+40°C (below 35°C within 24 hours)
Relative humidity: ≤95% (daily average) or ≤90% (monthly average)
Altitude:  ≤ 1000m
Structure and Function

Main Technical Parameters

Description

Unit

Data

Rated voltage

KV

11

Max. voltage

KV

12

Rated current

A

630

Rated short-circuit breaking current

kA

20/25

Mechanical life

Times

10000

Note:Please contact the factory to confirm the latest parameters

Outline and installation dimension

Cabinet Used VS1 11kV 630A Indoor Vacuum Circuit Breaker

 

Rated current(A) 630
Rated short-time withstand current(kA) 20,25
Interphase distance(mm) 210±1.

Product detail pictures:

Short Lead Time for Automatic Reset Circuit Breaker - Cabinet Used VS1 11kV 630A Indoor Vacuum Circuit Breaker – Aiso detail pictures

Short Lead Time for Automatic Reset Circuit Breaker - Cabinet Used VS1 11kV 630A Indoor Vacuum Circuit Breaker – Aiso detail pictures

Short Lead Time for Automatic Reset Circuit Breaker - Cabinet Used VS1 11kV 630A Indoor Vacuum Circuit Breaker – Aiso detail pictures


Related Product Guide:

Our advantages are lower prices,dynamic sales team,specialized QC,strong factories,high quality products and services for Short Lead Time for Automatic Reset Circuit Breaker - Cabinet Used VS1 11kV 630A Indoor Vacuum Circuit Breaker – Aiso, The product will supply to all over the world, such as: South Africa, Sweden, Tajikistan, With many years good service and development, we have a qualified international trade sales team. Our goods have exported to North America, Europe, Japan, Korea, Australia, New Zealand, Russia and other countries. Looking forward to build up a good and long term cooperation with you in coming future!
Leave Your Message
Send Your Inquiry Now