While using the "Client-Oriented" organization philosophy, a rigorous top quality command process, highly developed production devices and a potent R&D workforce, we normally provide high quality products, outstanding solutions and aggressive charges for Circuit Breaker In Substation, Polymer Lightning Arrester, Hv Voltage Transformer, We are very proud of the good reputation from our customers for our products' reliable quality.
Leading Manufacturer for Current Transformer - ZW6-12/630-16(20) Series outdoor high voltage vacuum circuit breaker – Aiso Detail:

General Description

ZW6-12/630-16(20) Series outdoor high voltage vacuum circuit breaker is used for rated voltage 12KV and below, three phases, AC50Hz, power system, to switch on/off loading current, over-current, and short circuit in rural or urban power network, and for similar application, also for sectionalizer of urban 12KV network.

Main Technical Parameters

Technical parameters of breaker as sheet 1

Item

Description

Unit

Data

1

Ratedvoltage

KV

12

2

Ratedinsulationlevel

1minwithstandvoltage

Dry

42

Wet

34

Lightningimpulsewithstandvoltage(peak)

75

3

Ratedcurrent

A

630

4

Ratedfrequency

Hz

50

5

Ratedshortcircuitbreakingcurrent

KA

12.51620

6

Ratedshortcircuitmakingcurrent(peak)

31.54050

7

Ratedpeakwithstandcurrent

31.54050

8

Ratedshorttimewithstandcurrent

12.51620

9

Operatingsequence

 

OC-0.3s-CO-180S-CO

10

Nosofbreakingratedshortcircuitbreakingcurrent

Times

30

11

Mechanicallife

10,000

12

RatedoperatingvoltageCTspringoperatingmechanismprovided

 

DC24,48V,AVDC110V,220V

13

Permissibleabradedthicknessofcontact

mm

3

14

Ratedcurrentofover-currentrelease

A

5

15

Weight

kg

130

Note:Please contact the factory to confirm the latest parameters

Breaker assembly and physical parameters as sheet 2

Item

Description

Unit

Data

1

Openingdistanceofcontact

mm

9±1

2

Overtravellingdistanceofcontact

3±1

3

Averageclosingspeed

s

1.0±0,2

4

Averageopeningspeed

0.6±0.2

5

Jumpingtimeofcontactatclosing

ms

≤2

6

Asychronyofthreephaseopening

7

Closingtime

s

≤0.1

8

Openingtime

Highestoperatingvoltage

≤0.06

Lowestoperatingvoltage

≤0.1

9

DCresistanceofeachphasecircuit

μΩ

≤200

10

Centraldistancebetweenphase(inarcextinguishingchamber)

mm

193

Note:Please contact the factory to confirm the latest parameters

Outline & Installation Size

3b4a06a0-9ab0-45e3-9324-dcb90789c827

Note: If user has any special requirement, please negotiate with our factory.


Product detail pictures:

Leading Manufacturer for Current Transformer - ZW6-12/630-16(20) Series outdoor high voltage vacuum circuit breaker – Aiso detail pictures


Related Product Guide:

The company upholds the philosophy of "Be No.1 in quality, be rooted on credit and trustworthiness for growth", will continue to serve old and new customers from home and overseas whole-heatedly for Leading Manufacturer for Current Transformer - ZW6-12/630-16(20) Series outdoor high voltage vacuum circuit breaker – Aiso, The product will supply to all over the world, such as: Algeria, Panama, Lithuania, With the aim of "compete with good quality and develop with creativity" and the service principle of "take customers' demand as orientation", we will earnestly provide qualified products and good service for domestic and international customers.
Leave Your Message
Send Your Inquiry Now