Factory For Us Step Down Transformer - LZJ(C,D)-10(Q) 10kV Epoxy Pouring Wholly Current Transformer – Aiso

Factory For Us Step Down Transformer - LZJ(C,D)-10(Q) 10kV Epoxy Pouring Wholly Current Transformer – Aiso
To meet the customers' over-expected pleasure , we have now our solid crew to supply our greatest all round assistance which includes marketing, sales, planning, production, top quality controlling, packing, warehousing and logistics for Zinc Oxide Lightning Arrester, Ac Step Up Transformer, Surge Arrester Grounding, We sincerely look forward to hearing from you. Give us a opportunity to show you our professionalism and enthusiasm. We have been sincerely welcome excellent friends from numerous circles at dwelling and overseas occur to cooperate!
Factory For Us Step Down Transformer - LZJ(C,D)-10(Q) 10kV Epoxy Pouring Wholly Current Transformer – Aiso Detail:

Indoor current transformers Summary

LZJ(C,D)-10Q Current transformer is of an all work-condition post type with epoxy pouring wholly sealed insulation, used for measurement of current and electric energy power as well as relay protection in the AC circuit of rated frequency 50Hz and rated voltage 10kV. This product is the whole sealing one designed on basis of previous LZJ(C, D)-10 product. Having overcome the disadvantage of the old product that the surface creep distance is too small to make Class S product, LZJ(C,D)-10Q current transformer can completely replace LZJ(C,D)-10 type, it can be widely used for HXGN1-10 box-type AC metallic enclosed ring main writ, HK-10D type ring main writ, HGKG-10 type ring main writ and other ring main writs.

Technical parameter

The performance of products is conformed to IEC standard and GB20840.2-2014 Current Transformer.

Rated insulation level:12/42/75kV

Load power factor: COS¢=0.8(Lag)

Rated frequency:50Hz

Rated secondary current:5A, 1A

Partial discharge level: In conformity to GB5583-85 standard, its partial discharge is not more then 20PC.

Surface creep distance:225mm, meeting polluted area grade II.

Main Technical parameter

Rated primary current(A) Accuracy class Rated secondary output(VA) Rated short time thermal current (KA virtual value) Rated dynamic stability current (KA peak)
0.2S 0.2 0.5S 0.5 10P10 10P15
5-300 0.2S/10P  0.2/10P  0.5S/10P  0.5/10P  0.2/0.5  0.2/0.2 10 10 10 10 15 15 100/1h 250/1h
400 45 112.5
500 56 140
600 15
800 20 20 80 200
1000 25

Outline and installation dimension

(Outline and installation dimension of LZJC-10Q current transformer with accuracy class 0.2)

Manufacturer Price 20kV Current Transformer With Good Quality

Contact us for more details and quotations


Product detail pictures:

Factory For Us Step Down Transformer - LZJ(C,D)-10(Q) 10kV Epoxy Pouring Wholly Current Transformer – Aiso detail pictures

Factory For Us Step Down Transformer - LZJ(C,D)-10(Q) 10kV Epoxy Pouring Wholly Current Transformer – Aiso detail pictures

Factory For Us Step Down Transformer - LZJ(C,D)-10(Q) 10kV Epoxy Pouring Wholly Current Transformer – Aiso detail pictures


Related Product Guide:

We have been ready to share our knowledge of advertising and marketing worldwide and recommend you suitable products and solutions at most competitive price ranges. So Profi Tools supply you best benefit of money and we're ready to create with each other with Factory For Us Step Down Transformer - LZJ(C,D)-10(Q) 10kV Epoxy Pouring Wholly Current Transformer – Aiso, The product will supply to all over the world, such as: Karachi, Paris, Argentina, We believe that good business relationships will lead to mutual benefits and improvement for both parties. We now have established long-term and successful cooperative relationships with many customers through their confidence in our customized services and integrity in doing business. We also enjoy a high reputation through our good performance. Better performance will be expected as our principle of integrity. Devotion and Steadiness will remain as ever.
Leave Your Message
Send Your Inquiry Now