With a complete scientific quality management system, good quality and good faith, we win good reputation and occupied this field for
Off Load Changeover Switch,
27kv Fuse Cutout,
Hv Current Transformer, We are now on the lookout ahead to even larger cooperation with abroad consumers dependant on mutual added benefits. When you are interested in almost any of our products, be sure to experience cost-free to make contact with us for more facts.
Factory directly Step And Down Transformer - LZZBJ9 20kV Current Transformer – Aiso Detail:
The current transformer is casting resin and fully enclosed product. It is used formetering electric energy and current, relay protection in therelay protection in the electrical system of rated frequtncy 50Hz or 60Hz and rated voltage 20KV. The transformers be executed according to the standards IEC44-1 and GB20840.1-2010, GB20840.2-2014 Current Transformer.
Type designation

Structural introduction
This type of current transformer is fully enclosed and post type. It is small and light. There are four fixing hole of 4-M10 on the bottom.
Technical parameter
1, Rated insulated level: 24/65/125KV
2, Rated secondary current: 5A, 1A
3, Rated primary current, accuracy combination, rated output, dynamic and thermal stability current.
4, The conditions of the partial discharge test according to GB20840.1-2010&GB20840.2-2014 Current transformer will be fulfilled without exception.
Dynamic thermal stability technical parameters
Note:
1, If being request, the measuring class can reach to 0.2S or 0.5S class.
2, We can make multi-trans formation-ratio current transformer of single measuring winding or single protivc winding, such as single measuring winding: 100-150-200/5A 0.2 class 10VA, Ith=31.5A
Single protective class: 100-150-200/5A, 5P15 class, 10VA, Ith=31.5A.
Main technical parameter
| Rated primary current(A) |
Accuracy class combination |
Rated output (VA) |
short-time thermal current (KA ) |
Rated dynamic current (KA ) |
| 0.2, 0.2S |
0.5, 0.5S |
10P10 |
10P15 |
| 30-150 |
0.2s/0.5s/10p 0.2s/0.5/10p 0.5s/0.5/10p |
10 |
10 |
15 |
15 |
200Iln |
500Iln |
| 150-200 |
31.5 |
80 |
| 200-300 |
45 |
112.5 |
| 300-400 |
63 |
130 |
| 600-800 |
15 |
20 |
15 |
80 |
160 |
| 1000-1250 |
| 1500-2000 |
15 |
20 |
30 |
20 |
100 |
160 |
Outline and installation dimension

Contact us for more details and quotations
Product detail pictures:
Related Product Guide:
To continuously increase the administration process by virtue of the rule of "sincerely, good religion and excellent are the base of company development", we commonly absorb the essence of linked goods internationally, and continually build new solutions to fulfill the requires of shoppers for Factory directly Step And Down Transformer - LZZBJ9 20kV Current Transformer – Aiso, The product will supply to all over the world, such as: Czech Republic, Panama, Croatia, Furthermore, all of our items are manufactured with advanced equipment and strict QC procedures in order to ensure high quality. If you are interested in any of our goods, please don't hesitate to contact us. We will do our best to meet your needs.