2018 Latest Design Fuse Cutout Price 200a - LW8A Outdoor High Voltage SF6 Circuit Breaker With Good Quality – Aiso

2018 Latest Design Fuse Cutout Price 200a - LW8A Outdoor High Voltage SF6 Circuit Breaker With Good Quality – Aiso
Our business promises all users of the first-class items and the most satisfying post-sale company. We warmly welcome our regular and new prospects to join us for Circuit Breaker Trip, Fuse Link For Transformer, Arrester, We welcome new and previous clients from all walks of lifestyle to get in touch with us for long term business relationships and mutual accomplishment!
2018 Latest Design Fuse Cutout Price 200a - LW8A Outdoor High Voltage SF6 Circuit Breaker With Good Quality – Aiso Detail:

132kV SF6 Circuir Breaker Application

Actastheprotectingandcontrollingunitforgridequipmentsandindustrialminingenterprises’equipments,LW8A-40.5 type outdoor SF6 circuit breaker is an outdoor device used in AC 50HZ three-phase 40.5KV power system.It is applicable to locations that need frequent operating in rated current or under repeatedly on/off short circuit current. Containing the current transformer for measurement and protection, it can directly replace SW2-35 less oil circuit breaker and various types of oil circuit breaker with transition bracket. It can also be used as a tie breaker and switching capacitor group situations with CT14 type spring mechanism.

110kV-132kV Circuit Breaker Features

Excellent breaking performance, short burning arc time, long life;

Mechanical life of more than 3000 times;

Operation frequently, each can be installed 12 current transformers;

New type SF6 MKZ pointer type density meter, pressure gauge reading is not affected by temperature changes;

Environmental Condition

Ambienttemperature:-30℃~+40℃

Altitude:≤3000m

Wind pressure:≤700Pa

Relative humidity:daily average relative humidity: ≤95%;monthly average relative humidity≤90;daily average saturated vapor pressure ≤2.2KPa;monthly average value ≤1.8KPa

Air pollution level:Ⅲ

Earthquake intensity:≤8 degree

The installation should be free from fire, explosion, severe vibration, chemical corrosion and serious pollution

 

110kV SF6 Brealer Main technical data

No. Item Unit Data
1 Ratedvoltage KV 110
2 Ratedcurrent A 2000/3150
3 Ratedfrequency HZ 50
5 Ratedshortcircuitbreakingcurrent KA 31.5/40
6 Rated short-circuitcurrent(peak) KA 100
7 Ratedshort-circuitwithstandcurrent KA 31.5/40
10 Ratedshortcircuitclosingcurrent(peak) KA 100
13 Electricallifeofratedshortcircuitbreakingcurrent times 20
14 Ratedshortcircuitduration s 4
15 Ratedlinechargingclosecurrent A 31.5
16 Ratedoperationsequence   O-0.3s-CO-180s-CO
17 Splittime ms ≤60

Please contact us for more details and price details.


Product detail pictures:

2018 Latest Design Fuse Cutout Price 200a - LW8A Outdoor High Voltage SF6 Circuit Breaker With Good Quality – Aiso detail pictures

2018 Latest Design Fuse Cutout Price 200a - LW8A Outdoor High Voltage SF6 Circuit Breaker With Good Quality – Aiso detail pictures

2018 Latest Design Fuse Cutout Price 200a - LW8A Outdoor High Voltage SF6 Circuit Breaker With Good Quality – Aiso detail pictures


Related Product Guide:

We always follow the principle "Quality Very first, Prestige Supreme". We have been fully committed to delivering our customers with competitively priced high-quality products and solutions, prompt delivery and experienced services for 2018 Latest Design Fuse Cutout Price 200a - LW8A Outdoor High Voltage SF6 Circuit Breaker With Good Quality – Aiso, The product will supply to all over the world, such as: Juventus, Wellington, US, With well educated, innovative and energetic staff, we are responsible for all elements of research, design, manufacture, sale and distribution. By studying and developing new techniques, we are not only following but also leading fashion industry. We listen attentively to the feedback from our customers and provide instant replies. You will instantly feel our professional and attentive service.
Leave Your Message
Send Your Inquiry Now